SP200/210 Maxon SP200/210 Radio
Issue 1.0 APPENDIX A - ACC-2 003 INTERFACE BOX
03/01 Page 11-1
11 APPENDIX – ACC-2003 ALIGNMENT BOX

11.1 Purpose

This Section is reproduced from the ACC-2003 User Guide and provides information on the operation
of the ACC-2003 Interface Test Jig.
This jig is used for the Service adjustment of the SP200/210 radio.
The Calibration program (Calibration.exe) is used to al low the setting of ASIC conditions within the
radio.
Default ASIC conditions can be programmed into a radio and then repeated from radio to radio.
For non-ATE conditions, such as Repair or Adjustm ent, the various parameters can be manually
adjusted.

11.2 Test Equipment

A Standard Radio Communication Test Set, oscillosc ope and 7.5V Power supply are required.

11.3 Calibration Program

11.3.1 Operation

Ensure that the Power Switch is OFF on the Interface box. Switch on the S200/210 and place
the volume control at the half-way position.
Place the ATE/MANUAL switch in the ATE positio n (switch down). Place the Audio EN switch in the
ON position (switch down) and PTT off. Switch the T est Jig on by operating the on/off switch.
The letter Ashould be displayed on the SP200/210.
On the PC, start the Calibration.exe program. Figure 11-1 s hould be displayed.
Figure 11-1 – Calibration Program Initial Screen