Select the required band and press Enter. Figure 11-2 will be displayed.

Figure 11-2 - Calibration Program Primary Screen

To dedicate the Communication Port, select Configuration and enter the relevant port number.

Selecting EEPROM loading will retrieve the current ASIC values, stored in the radio. This is used for the alignment of the radio. This selection should not be made if the EEPROM is empty (new EEPROM) or if the radio is in the middle of another operation.

If there is a Communications error, check the setting BEFORE turning the power on at the Interface Box.

Press ‘ESC’ at error message and then ‘N’ to try again.

To write default values (see Default Settings) select ‘EEPROM’ Refill. This writes the default ASIC values and the default frequencies.

To program the radio with the altered ASIC values, press F6.

Note: If the channel shows ‘Unlock’ under the PLL status (top right) this implies that the channel does not have a valid frequency programmed into the radio. This will also occur if the start-up sequence is not observed, see Section 11.1.

11. APPENDIX A – ACC-2003 ALIGNMENT BOX -

Issue 1.0

Page 11-2

03/01

Page 86
Image 86
Maxon Telecom SP210, SP200 service manual Calibration Program Primary Screen, Appendix a ACC-2003 Alignment BOX