Maxon SP200/210 Radio SP200/210
11. APPENDIX A – ACC-2003 ALIGNMENT BOX - Issue 1.0
Page 11-2 03/01
Select the required band and press Enter. Figure 11-2 wil l be displayed.
Figure 11-2 - Calibration Program Primary Screen
To dedicate the Communication Port, select Configuratio n and enter the relevant port number.
Selecting EEPROM loading will retrieve the curren t ASIC values, stored in the radio. This is used f or
the alignment of the radio. This selection should not be m ade if the EEPROM is empty (new
EEPROM) or if the radio is in the middle of another operat ion.
If there is a Communications error, check the setting BEFO RE turning the power on at the Interface
Box.
Press ‘ESC’ at error message and then ‘N’ to tr y again.
To write default values (see Default Settings) select ‘EEPROM’ Refill. This writes the default ASIC
values and the default frequencies.
To program the radio with the altered ASIC values, press F 6.
Note: If the channel shows ‘Unlock’ under the PLL status (top righ t) this implies that the channel does
not have a valid frequency programmed into the radio. T his will also occur if the start-up sequence is
not observed, see Section 11.1.