Maxon SP200/210 Radio

SP200/210

This completes the transmitter alignment process.

4.5.6 Receiver Alignment

Audio Volume Level

a.Set the test set to the appropriate frequency at –47dBm with 1kHz tone modulation at 60% system deviation:

12.5kHz channel spacing 1.5kHz dev. or 20kHz channel spacing2.4kHz dev. or 25kHz channel spacing3kHz dev.

b.Select Channel 1.

c.With the calibration program running on the PC, select Rx_Vol.

d.Turn the volume control to maximum.

e.Using the PageUp and PageDown keys, press until the desired maximum volume level is achieved.

Note: -17.5dB corresponds to 2.10V (+/-0.2V) into 4 ohm speaker.

At maximum volume, nominal distortion is 10%.

f.Write the changes to the radio.

It may be necessary to carry out adjustment of the squelch setting, see Section 4.5.4.

This completes the receiver alignment process.

The following parameters would NOT normally be adjusted unless specific environmental conditions necessitate a change:

INTRIM on the receiver (Audio from IF IC.)

SATRIM on the receiver (gain received – sub audible tone)

Refer to the ACC-2003 User Guide for details.

INSTALLATION, COMMISSIONING & ALIGNMENT -

Issue 1.0

Page 4-14

03/01

Page 28
Image 28
Maxon Telecom SP210, SP200 Receiver Alignment, Audio Volume Level, At maximum volume, nominal distortion is 10%