5-3

Trouble shooting chart

All output voltages on the power board is 0V or deviated.

All output voltages on the power board is 0V or deviated

Yes

Check whether

F1 is blown

No

Check whether there is

300V on C1 or C2.

Yes

Check whether 100KHz oscillating signal on Pin6 of U1

Yes

Yes

No

No

Replace F1

Replace C1&C2 if D1, D2, D3, D4 are normal.

Check/ replace U1.

U1(PIN 3 - RC waveform)

U1(PIN 8 - Drain waveform)

Check if +5V, +12V are

No

short.

 

Yes

 

 

 

Check whether the components in the

 

short-circuit voltage are defected or eroded.

 

 

 

Check whether U1 are eroded.

Page 15
Image 15
Philips DVP3320/55 service manual All output voltages on the power board is 0V or deviated