Safety instruction, Warning & Notes

Safety instruction

1. General safety

Safety regulations require that during a repair:

. Connect the unit to the mains via an isolation transformer.

.Replace safety components indicated by the symbol , only by components identical to the original ones. Any other component substitution (other than original type) may increase risk of fire or electrical shock hazard.

Safety regulations require that after a repair, you must return the unit in its original condition. Pay, in particular, attention to the following points:

.Route the wires/cables correctly, and fix them with the mounted cable clamps.

.Check the insulation of the mains lead for external damage.

.Check the electrical DC resistance between the mains plug and the secondary side:

1)Unplug the mains cord, and connect a wire between the two pins of the mains plug.

2)Set the mains switch the “on” position (keep the mains cord unplug).

3)Measure the resistance value between the mains plug and the front panel, controls, and chassis bottom.

4)Repair or correct unit when the resistance

measurement is less than 1M .

5)Verify this, before you return the unit to the customer/user (ref. UL-standard no. 1492).

6)Switch the unit “off”, and remove the wire between the two pins of the mains plug.

2.Laser safety

This unit employs a laser. Only qualified service personnel may remove the cover, or attempt to service this device (due to possible eye injury).

Laser device unit

Type

: Semiconductor laser GaAlAs

Wavelength

: 650nm (DVD)

 

: 780nm (VCD/CD)

Output power

: 7mW (DVD)

:10mW (DVD /CD)

Beam divergence: 60 degree

Note: Use of controls or adjustments or performance of procedure other than those specified herein, may result in hazardous radiation exposure. Avoid direct exposure to beam.