Reliability

MTBF:100,000 POH (25% duty cycle at room temperature)

-15

Error rate: 10 after error correction

-12

10 hard read error

Environmental Tolerance

 

Operating

Non-operating

Temperature:

+5 ￿C ~

+40 ￿C -20 ￿C ~ +55 ￿C

 

+41

￿F ~

+104 ￿F

-4 ￿F ~ +131 ￿F

Humidity:

20%

- 80% RH,

 

15% - 80% RH,

 

non-condensing

non-condensing

Physical Characteristics

Dimension:

 

 

146 x 42.5 x 210 mm (W x H x D)

 

 

 

 

 

 

typical

Weight:

 

 

0.9 Kg

Front panel:

 

 

Stop/Eject button

 

 

 

 

 

 

Audio Play/Skip button

 

 

 

 

 

 

Emergency disc eject hole

 

 

 

 

 

 

Rotary volume control knob

 

 

 

 

 

 

Disc Ready/Data Seek LED indicator

 

 

 

 

 

 

Headphone jack

Rear Panel:

 

 

Power supply connector

 

 

 

 

 

 

IDE interface connector

 

 

 

 

 

 

Master/Slave configuration jumpers

 

 

 

 

 

 

Audio line output

 

 

 

 

 

 

Digital audio output

 

 

 

 

 

 

Testing jumper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 