Technical Information

Serial terminal

The serial connector which is on the connector panel of the projector conforms to the RS-232C interface specification, so that the projector can be controlled by a personal computer which is connected to this connecter.

Connection

D-sub 9 pin (male)

Serial terminal (female)

Computer

Pin assignments and signal names

Pin No.

Signal name

Contents

A

 

NC

B

TXD

Transmitted data

C

RXD

Received data

D

 

NC

E

GND

Earth

F

 

NC

G

RTS

Connected internally

H

CTS

 

I

 

NC

Communication settings

Signal level

RS-232C

Character length

8 bits

 

 

 

 

Sync. method

Asynchronous

Stop bit

1 bit

 

 

 

 

Baud rate

9 600 bps

X parameter

None

 

 

 

 

Parity

None

S parameter

None

 

 

 

 

Basic format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The data streaming from the computer will

 

STX

Command

:

 

Parameter

ETX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

start with STX, and proceed to Command,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

 

byte

 

 

 

 

 

 

 

 

Parameter and end with ETX. You can

 

 

 

 

1 byte

 

 

End

 

 

3 bytes

1 byte -

 

(02h)

 

 

 

 

(03h)

add the required parameter.

 

 

 

 

 

 

 

4 bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The projector can not receive any command for 10 seconds after the lamp is switched on. Wait 10 seconds before sending the command.

If sending multiple commands, check that a response has been received from the projector for one command before sending the next command.

When a command which does not require parameters to be sent, the colon (:) is not required.

If an incorrect command is sent from the personal computer, the ER401 command will be sent from the projector to the personal computer.

Appendix

ENGLISH - 45

Page 45
Image 45
Philips PT-FW100NTU manual Serial terminal