24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 5: CONTROLLER OPERATION

5.1 Operating Fryers with Thermatron Controllers (cont.)

MANUAL FILTER POWER SWITCH (older systems with built-in filtration) – Controls power to the filter pump in the event the primary system fails. Fryer Power Switch should be in "OFF"

position when in use.

HIGH-LIMIT RESET – Located under control panel. Must be manually reset if the fryer exceeds high-limit setpoint.

FILTER RESET BREAKER (7 Amp Circuit Breaker- 120VAC or 5 Amp Circuit Breaker- 230VAC) – the breaker is inline between the filter switch and the pump. Ensure filter power is off prior to resetting or replacing.

5 AMP (115VAC) or 2 AMP (230VAC) FUSE – each fryer circuit is protected by a 5-amp (115VAC) or 2-amp (230VAC) fuse located under the control panel or inside the cabinet.

5-2