24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS
3.6 Gas Inputs (cont.)
Gas Type | Orifice Part Number* |
|
|
Natural | |
Propane |
* Orifice sizes are listed for altitudes of 2000 feet and less.
Burner Adjustments- 24G Series
Loosen this screw to adjust burner damper for optimum flame.
Ensure orifice tip is approximately 20 mm from the upper damper slot.
20 mm
Natural (G20/G25) Gas: Maximum Opening
Propane/LP (G31) Gas: 15 mm Opening
WARNING
If gas odors are detected, the gas supply MUST be shut off at the main
the local gas company or authorized service agency contacted for immediate service.
3.7 Gas Conversion Procedures
DANGER
This appliance was configured at the factory for a specific type of gas. Converting from one
gas type to another requires the installation of specific
Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.5 of this manual.
See page