Frymaster 24G Series operation manual 24G SERIES FLATBOTTOM GAS FRYERS, Fryer Operations

Models: 24G Series

1 46
Download 46 pages 26.17 Kb
Page 33
Image 33
Manual background

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 4: FRYER OPERATIONS

4.1.1 Pilot Lighting Procedures, Standing Pilot (cont.)

7.Push and hold the knob in and apply a lighted match or taper to the pilot burner head. Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.

4.1.2 Pilot Lighting Procedures, Electronic Ignition Systems

Manual background WARNING

Never use a match or taper to light pilot on this ignition system.

24V Gas Valves for Electronic Ignition: Rotate the knob counter-clockwise to the ON position. Rotate the knob clockwise to turn the gas valve to OFF.

Off position

On position

1.Turn gas valve knob to ON.

2.Turn electric power on with the appropriate rocker switch.

3.The ignition module will energize the pilot gas supply and the ignitor. The ignitor spark will ignite the pilot gas. The presence of the pilot flame is then proved by a flame sensor, which sends a signal to the main gas supply, opening the valve. The Thermatron controller controls the fryer after ignition.

Manual background WARNING

In the event of prolonged power failure, the ignition module will shut down and lock out the

system. Turn the unit power "OFF" and then back "ON" after power has been re-

established.

4.If the pilot flame fails, the ignition module will shut down and lock out the system. To restart, turn the electric power off, wait approximately 5 minutes for the system to recycle itself, then turn the power on again. Repeat Steps 1-3.

4-4