Frymaster 24G Series operation manual Boil-OutProcedure

Models: 24G Series

1 46
Download 46 pages 26.17 Kb
Page 34
Image 34
4.2 Boil-Out Procedure

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 4: FRYER OPERATIONS

4.2 Boil-Out Procedure

NOTE: Consult store operational procedures to ensure that frypot boil-out is an approved procedure before proceeding.

Manual background DANGER

Never leave the fryer unattended during the boil-out process. If the boil-out solution boils

over, turn the fryer off immediately and let the solution cool for a few minutes before

resuming the process.

Manual background WARNING

Do not drain boil-out solution into a shortening disposal unit, a built-in filtration unit, or a portable filter unit. These units are not intended for this purpose, and will be damaged by the solution.

Manual backgroundWARNING

Leave fryer OFF for a minimum of 10 minutes prior to filtering to allow frypot heat to

dissipate. Frypot damage can occur if the shortening is drained immediately after turning

fryer off.

1.Empty frypot and pour in cleaning solution concentrate. Add water to the upper oil level line scribed in the back of the frypot.

2.Thermatron Controller-Equipped Fryers: Set temperature dial to 225°F (107ºC), just above that of boiling water.

3.Filtration/Boil-Mode-Equipped Fryers: Turn fryer power switch to On. Press the fryer-reset switch (if applicable). Turn the boil-out switch to On.

4.The main burner will ignite.

5.Thermatron Controller-Equipped Fryers: Reset the controller-dial to 200°F (93°C).

6.The burners should shut off, just as the boil-out solution reaches setpoint.

Manual background CAUTION

If the pilot and main burner go out, the fryer(s) MUST be left completely shut down at least 5

minutes before lighting.

7.The burners will heat the boil-out solution to a simmer. Simmer the solution for approximately 45 minutes. Wearing protective gloves, scrub the bottom and sides of the frypot with the frypot brush (optional on certain models), being careful not to disturb the temperature and high-limit thermostat sensing probes.

4-5