3.7 Gas Conversion Procedures (cont.)

NON-CE UNITS ONLY:

See gas valve illustration below for reference when performing gas valve conversions.

When converting from natural gas to propane (or vice-versa), the following procedures apply:

Burner orifices and pilot orifice MUST be replaced (see page 3-11 for required component part numbers).

Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 3-11 for gas types and pressures).

After adjustment, replace the adjustment-screw cover.

Factory MUST be notified so the conversion can be documented and a new rating plate can be sent out.

Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the tables on page 3-11.

Conversions can only be executed by qualified, factory-authorized personnel.

Pilot pressure

Pressure flow adjustment

Pilot pressure

Thermocouple

adjustment (remove

adjustment

Connection

cover screw to access)

(remove cover screw to access)

 

 

Manual background Vent Tube Manual background

Connection

Pilot gas supply

ON/OFF Gas

OFF Button

ON Button- Pilot

connection.

Knob

 

Gas-Flow

Non-CE gas valve (typical)

CE gas valve (typical)