5.1 Operating Fryers with Thermatron Controllers

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 5: CONTROLLER OPERATION

5.1 Operating Fryers with Thermatron Controllers

24G Series Flatbottom gas fryers come equipped with a solid-state Thermatron or electronic thermostat controller, and are operated with the following controls:

Thermatron Controller

Fryer Power Switch: Turns fryer on

and off.

Boil-Out Switch (Optional): operates only in "Thermatron" mode. When "ON", this switch by-passes the Thermatron melt-cycle and allows the water temperature to reach 196°F.

High-Limit Reset Breaker

(location varies according to system): This must be manually reset if fryer exceeds high-limit setpoint.

O F F

O F F

POWER

O

N

FRYER

R

E

S

E BOIL OUT T

O

N

Drain Reset Switch (Optional): Resets drain safety switch after closing drain valve. Drain valve must be completely closed prior to resetting switch.

Manual Filter Power Switch (if equipped with filter system): Connects/disconnects power to filter pump if primary system fails. Fryer power switch should be "OFF" when filter is in use.

5 Amp (230VAC) Filter Reset Breaker (if equipped with filter system): Inline between the filter pump and the filter power switch. Ensure power is "OFF" before resetting or replacing.

FRYER POWER SWITCH – This switch turns the fryer on and off. When the power switch is in the "ON" position, the indicator light will be lit when calling for heat.

BOIL-OUT SWITCH (Optional) – When the Boil-Out switch is "ON", it will bypass the melt cycle, and allow the water temperature to reach approximately 196°F (91°C).

DRAIN RESET SWITCH (Optional) – Resets drain safety switch after draining the fryer. Drain valve must be closed completely before resetting switch.

5-1