BDR-203/BDC-203 Command Reference Manual Version 0.90

4.1 BLANK Command

This command is valid for CD-RW and DVD-RW media. The Immed bit is supported.

The READ DISC INFORMATION Command, the READ TRACK INFORMATION Command and the TEST UNIT READY Command are used to detect completion of the blank operation. While blank operation is performed by the BLANK Command that the Immed bit is set to one, the drive terminates these commands with the Check Condition status, LOGICAL UNIT NOT READY, OPERATION IN PROGRESS (2/04/07).

The drive supports following Blanking Type for CD-RW and DVD-RW media.

Table 2 - Blank Type

Code

Name

CD-RW media

DVD-RW media

000b

Blank the disc

Yes

Yes

001b

Minimally blank the disc

Yes

Yes

010b

Blank a Track

No

-

011b

Unreserved a Track/RZone

No

No

100b

Blank a Track/RZone Tail

Yes

No

101b

Unclose the last Session/Border

ONFIDENTIAL

No

No

110b

Erase Session/Border

No

No

4.2 CLOSE TRACK/SESSION Command

The Immed bit is supported.

The READ DISC INFORMATION Command or READ TRACK INFORMATION Command is used to detect completion of the close operation. During a close operation performed by the CLOSE TRACK/SESSION Command whose Immed bit is set to one, the drive terminates these commands with the Check Condition status, LOGICAL UNIT NOT READY, OPERATION IN PROGRESS (2/04/07).

 

 

Note: The TEST UNIT READY Command may be used to ide ti y the completion of close operation.

 

 

The valid Close Function field values are extended f r ha dli g the +R/+RW media in the MMC-5 rather than the SFFC

 

 

INF-8090i.

C

 

 

 

 

 

This command is not valid for BD-RE.

IONEER

 

Table 3 – Valid Close Function and Media

 

 

Close

M dia

 

 

 

Function

 

 

 

 

000b

+RW

 

 

 

 

CD-R/RW

 

 

 

001b

DVD-R/RW/R DL

 

 

 

 

 

P

+R, +R DL

 

 

 

 

 

 

 

 

BD-R

 

 

 

 

CD-R/RW

 

 

 

010b

DVD-R/RW/R DL

 

 

 

Formatted DVD-RW

 

 

 

 

+R/+RW/+R DL

 

 

 

 

BD-R

 

 

 

011b

Formatted DVD-RW

 

 

 

+RW

 

 

 

 

 

 

 

100b

+R DL

 

 

 

101b

+R/+R DL

 

 

 

110b

+R/+R DL

 

 

 

BD-R

 

 

 

 

 

Page 8