Pioneer PDP-425CMX manual Precautions, Self-diagnosis Function, Error Message Remedy

Models: PDP-425CMX

1 24
Download 24 pages 50.37 Kb
Page 22
Image 22

Precautions

5.0Precautions

1)If the power shuts down and stays OFF for a long period, an internal problem has probably occurred (failing part, etc.).

Turn OFF the main power switch on the Plasma Display then wait 1 to 2 minutes and try turning the power ON again. If the power goes OFF again, the display need to be serviced.

If the display operates normally, the power reset has cleared the issue.

2)When an image (still image, telop, etc.) is shown on the screen for a long period, there is a possibility that the image could be burned in. This should be managed by making necessary changes in the imaging software, display method, system configuration etc.

3)The following kinds of input signals could cause inferior image quality (When a PDA-5003/PDA-5004 is used).

Video signal that has been dubbed (copied) repeatedly

Copyright-protected signals

Scrambled cable TV signals

Signals with a sync signal and video signal that are extremely out of phase

4)The fan starts operating when the surrounding temperature is greater than 32 °C (the fan rpm becomes faster as the temperature increases, this is normal).

5)Screen-saver function (still image detection)

When an image having little motion such as a photograph or PC screen is displayed continuously, the may appear dimmer. To protect the plasma panel, the screen-saver function detects images with little or no motion and automatically adjusts the brightness. This action is not an indication that the display is failing.

Time until the screen-saver function operates:

Normal-operation mode/menu mode: Approximate 3 minutes after the power is turned ON or after the input is switched.

7Self-diagnosis Function

When there is an operating or connection error, a message appears on the screen. After reading the contents of the error message, check the condition of the unit.

Error Message

Remedy

CAUTION

The current signal input is not supported by the unit. Check the table of supported

OUT OF RANGE

input signals on pages 94 - 97 and change the output signal setting.

UNSUPPORTED SIGNAL

 

SIGNAL NG

 

 

 

WARNING

Turn OFF the main power.

THERMAL ALERT

Check whether the surrounding temperature is high.

SHUT DOWN

If the cooling vents on the display are blocked, remove the obstacles blocking the

 

vents.

 

 

WARNING

There is a problem with the fan. Immediately turn OFF the power and contact the

FAN FAILURE

Pioneer service center or dealer.

SHUT DOWN

 

 

 

ERROR

An invalid operation was attempted. Check the input signals, connections and

INVALID KEY ENTRY

settings.

 

 

SHUT DOWN

Turn the main power OFF, wait 1 or 2 minutes and turn the power ON again. If the

 

problem still persists, remove the power plug from the outlet and contact a Pioneer

 

service center or dealer.

 

 

22

Page 22
Image 22