Problems commonly mistaken as breakdown

 

Problem

 

Possible Solution

 

 

 

 

The screen is displayed in a

Check the input signal compatibility chart (page 26).

 

small size.

Is the correct screen size selected? (page 16)

• Letter breakup on screen.

• Adjust using “SCREEN” mode on the menu screen (page 19).

 

 

 

If there is still no improvement, this unit may be limiting the displayable range. Check the

 

 

 

personal computer input signal compatibility chart (page 26).

A sharp sound is sometimes

Expansion/contraction caused by surrounding temperature change may result in sound being

 

heard from the cabinet.

 

heard from the cabinet. This is not a malfunction.

Bright portions of image

• When the input signal’s level is too high, the bright portions may appear to be losing their intensity.

 

appear to be losing intensity.

 

Increase the adjustment level of the contrast and check the picture (page 18).

Speckles or noise appears on

May be caused by radio wave interference from appliances with motors such as hair dryers,

 

screen.

 

electric vacuum cleaners, electric power drills, ignition systems of cars, motorcycles etc., switch

 

 

 

devices such as thermostats etc., neon signs or electrical discharge from power lines etc..

Stripes appear on the screen.

May be caused by radio wave mingling from TV station, FM station, amateur radios, public radios

 

 

 

(simplified radios) etc., or a nearby personal computer, TV, or video/audio component.

 

 

A strong electromagnetic field may cause picture distortion and similar problems.

Operation is not possible.

External influences such as lightning strike, static electricity etc., may cause improper operation.

 

 

 

In this case, operate the unit after first turning the main power ON/OFF, or unplugging the power

 

 

 

cord and re-plugging it in after 1 to 2 minutes.

Sound is heard from inside

Sound of fan revolving. This is not a malfunction.

 

the unit.

 

 

 

 

 

 

Information

Although this unit incorporates high precision technology in its design, please understand that there may be extremely slight pixel breakup, or light emission fault.

Note

In order to protect this unit’s panels and circuitry, the revolving speed of the interval fan will be automatically increased in order to cool the inside of the unit when the surrounding temperature exceeds 40 °C. (The sound of the fan will become louder at this time). Please operate this unit in a location with a surrounding temperature under 40 °C.

About the plasma panel’s protection function

The brightness of this display will deteriorate slightly when an image with little movement such as a photograph or computer image is continuously displayed. This is caused by the plasma panel’s protection function which detects images with slight movement and automatically adjusts brightness to protect the display, and is not a malfunction.

This function starts approximately 5 minutes after the power has been turned on or after input has been

switched.

Additional

Additional cautions

If the power is automatically turned off during operation of this unit, the following reasons may be the cause.

1 Is the POWER SAVE mode set to “MODE1” or

“MODE2”? (page 17)

2The surrounding temperature has risen above 40 °C.

Please operate this unit in a location with a surrounding temperature under 40 °C.

3The vents are blocked or the internal temperature has risen abnormally due to abnormal heat generation of internal parts etc..

If the power is automatically turned off for a reason other than the above reasons, there could be a malfunction. In this case, unplug the power cord from the power outlet and request repair from your nearest sales outlet.

The plasma display panel of this unit is very bright and viewing it a close distance will cause eye strain.

We recommend that you view the screen from a suitable distance (3 to 6m).

About the self diagnosis mode

Messages appear on the bottom of this unit’s screen to indicate operation or connection faults. After message

confirmation, check the condition of the unit.

If this message appears

Please do this

OUT OF RANGE

• A incompatible signal is being

or

input. Check the PC input signal

PLEASE CHANGE

compatibility chart on page 26

RESOLUTION

and change the output signal

OR REFRESH RATE

setting on the computer side.

THERMAL WARNING!

• Turn off main power (page 14).

PLEASE SHUT DOWN

• Has the room temperature

 

exceeded 40 °C? Reduce the

 

room temperature.

 

• If the unit’s vents are blocked,

 

unblock them.

 

 

24

<ARE1350> En

Page 28
Image 28
Pioneer PDP-502MXE manual Problems commonly mistaken as breakdown, About the self diagnosis mode, Additional cautions

PDP-502MXE specifications

The Pioneer PDP-502MXE is a remarkable plasma display panel that garnered attention in the home entertainment market due to its superior image quality and exceptional design. Launched in the early 2000s, the PDP-502MXE was a leading model in Pioneer’s lineup of high-definition plasma televisions, showcasing cutting-edge technology that set new standards in the industry.

One of the standout features of the PDP-502MXE is its 50-inch screen, which makes it an ideal choice for home theaters and larger living spaces. The display boasts a native resolution of 1024x768 pixels, providing stunning image clarity and detail. The plasma technology employed in this model allows for deep blacks and vibrant colors, delivering a dynamic range that enhances movie-watching experiences and visual content.

The PDP-502MXE supports multiple aspect ratios and allows users to choose between 4:3 and 16:9, making it versatile for various types of media. It comes equipped with advanced video processing capabilities, ensuring that even lower-resolution signals are upscaled effectively, resulting in a smooth viewing experience. The inclusion of a range of inputs, such as HDMI and component video, makes it compatible with many external devices, including DVD players and gaming consoles.

Additionally, Pioneer integrated their proprietary technologies into the PDP-502MXE, such as the PureCinema technology, which improves motion handling by reducing blurriness during fast-moving scenes. The display also features a filter that minimizes reflections, allowing it to perform admirably in different lighting conditions.

The PDP-502MXE’s design is another highlight, featuring an ultra-slim profile that enhances its aesthetic appeal. The panel's industrial design is complemented by minimal bezels, making it a stylish addition to any home setup. The build quality of the PDP-502MXE reflects its premium positioning, ensuring durability alongside functionality.

In summary, the Pioneer PDP-502MXE is a powerful plasma display that combines impressive visual performance with sleek design. Its advancing technologies, compatibility with various media formats, and stylish aesthetics make it an enduring choice for enthusiasts of high-quality home entertainment systems. Although newer technologies have emerged since its release, the PDP-502MXE continues to be remembered for its significant contributions to the evolution of display technology.