E3 51 72 Trimming Title Preset
The command presets the trimming title number.
Values are
Trimming title number executed by ”E1:51:75 Trimming” command is specified by
E5 51 73 Trimming In Preset
The command presets the trimming In Point. When the unit is stopped, the trimming IN point, executed by “E1:51:75 Trimming”, is specified by
E5 51 74 Trimming Out Preset
The command presets the trimming Out Point. When the unit is stopped, the trimming OUT point, executed by “E1:51:75 Trimming”, is specified by
E1 51 75 Trimming
This command trims the current title by creating a new title. When the unit is stopped, the title specified by ”E3:51:72 Trimming Title Preset” is trimmed from the IN point (specified by ”E5:51:73 Trimming In Preset”) to the OUT point (specified by ”E5:51:74 Trimming Out Preset”) then made into another title. With the ”E1:51:8F Mode Sense” command, it is possible to know if the trimming is finished. Issuing ”E1:51:81 Title Number Sense” before and after the trimming confirms that the number of titles in the selected project have increased after the trimming. If the number of titles has not increased, the trimming has failed so error handling should be executed.
E1 51 83 HDD Capa Sense
This command returns remaining capacity of the internal HDD, E3 51 93 n n, HDD Capa(GB) where nn is the capacity.
Ex: 102GB (0x02, 0x01)
E3 51 93 HDD Capa(GB)
When the unit receives the ”E1:51:83 HDD Capa Sense” command, the remaining capacity of the internal HDD is returned. The remaining capacity is specified in Gbytes by
DATA – 2 | DATA – 3 | ||
|
|
|
|
10 | 1 | always | 100 |
GBs | GBse | 0 | GBs |
|
|
|
|
MSD | LSD | MSD | LSD |
E1 51 8F Mode Sense
This command returns Mode Data E2 51 9F XX where XX is the code.
Ex: 01l:Recording, FF:RecError, 71:Title Delete, 75:Trimming
Page 12 of 18