Changing this unit’s settings

Changing the MIDI settings

The following buttons are used to change the MIDI settings:

[TAP] button: Used as the Enter button.

[AUTO] button: Used as the Cancel button.

[NUDGE (+, –)] button: Used to select items.

1Turn on this unit’s power while pressing the [QUANTIZE] button.

This unit starts up in the mode for changing the MIDI settings. The setting items are displayed on the BPM display.

2 Press the [+] or [–] side of the [NUDGE (+, –)] button.

Select whether to change the MIDI channel or MIDI button type.

If [CH] or numbers are displayed: MIDI channel changing mode

If [btn] or letters are displayed: MIDI button type changing mode

3 Press the [TAP] button.

Switch to the mode for changing the MIDI channel or the one for changing the MIDI button type.

The MIDI channel number or MIDI button type flashes on the BPM display.

4 Press the [+] or [–] side of the [NUDGE (+, –)] button.

Select and change the MIDI channel or MIDI button type. The values below can be selected for each of these.

MIDI channel: [1] to [16]

MIDI button type: [tGL (toggle)] or [trG (trigger)]

5 Press the [TAP] button.

The selected setting is stored.

The stored setting flashes rapidly on the BPM display.

!When this unit’s power is turned off, the mode for changing the MIDI settings is quit.

!The settings on this unit upon shipment from the factory are as follows:

MIDI channel: [1]

MIDI button type: [tGL (toggle)]

Using the update function

!Do not turn off this unit’s power during the updating procedure.

1Turn on this unit’s power while pressing the [HOLD (MUTE)] and [TAP] buttons.

This unit starts up in the updating mode.

The current firmware version number is displayed on the BPM display, and the right edge of the [OUTPUT] level indicator flashes.

2Insert the SD memory card on which the update file is stored into the SD memory card slot of this unit.

Updating starts.

The [OUTPUT] level indicator lights to indicate the progress of updating. Once all segments of the [OUTPUT] level indicator are lit, updating is completed.

!If an error occurs during updating, the type of error is indicated by the BPM display and the number of segments of the [INPUT] level indicator that are lit.

BPM

Lit segments of the

Type of error

display

[INPUT] level indicator

 

E00

 

Updating error

E10

 

Updating error

 

 

 

E20

 

Updating error

E30

 

Updating file not detected

 

 

 

E40

 

Updating file corrupt

E50

 

SD memory card reading error

 

 

 

E60

 

Memory clearing error

E70

 

Memory writing error

 

 

 

E80

 

Memory verification error

E90

 

SD memory card error

 

 

 

3-digit number

 

Updating completed normally

 

 

 

Temporarily changing the MIDI channel for the RMX-1000 Plug-in

Even when this unit is not in the mode for changing the MIDI settings, it is possible to temporarily change the MIDI channel.

1Press the [+] or [–] side of the [NUDGE (+, –)] button while pressing the [BANK] button.

The MIDI channel number appears on the BPM display.

2 Release the [BANK] button.

!The MIDI channel changed in this way is reflected on this unit until the power is turned off.

22En