3.2FRYER TROUBLESHOOTING
Refer to this section to correct common problems that may be encountered in equipment operation.
Fryer does not work.
Will the | NO |
| |
pilot light? |
|
YES
Does pilot
remain lit after NO Unitrol Knob is
released?
|
|
|
|
| Is the gas |
|
|
|
| NO | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| supply |
|
|
|
|
|
| |||||
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| valve open? |
|
|
|
| ||||||||||
|
|
|
|
|
|
| YES |
|
| ||||||||
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Purge air from gas |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| line (1.5.2) |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
| Is all the air |
| NO | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| purged from the |
|
| |||||||||||||
|
|
|
|
| |||||||||||||
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
| gas line? |
|
|
| ||||||||
|
|
|
|
|
|
|
|
| YES |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
Open the gas valve and light pilot (1.5.2)
Is High Limit | YES |
| |
Switch open? |
|
NO
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NO |
|
| Contact a |
|
| |||
| Will Limit |
|
| |||||||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Qualified |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
switch reset? |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| Technician. |
| |||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
YES
YES |
| Purge air from gas line by |
|
|
|
| |
|
| placing the Unitrol Valve |
|
| knob in PILOT and holding |
| |
|
| in for approx. 1 minute. |
|
|
|
|
|
Contact a
Qualified
Technician.
Reset & Light Pilot
Does pilot
go out when the YES temperature increases?
NO
Contact a Qualified
Technician.
Does the Main | NO |
| |
burner light? |
|
YES
If the main burner is lighting but not performing properly refer to Chapter 1 to verify proper installation or contact a qualified technician.
| Is the Unitrol gas |
|
| YES | |||
|
|
|
|
|
| ||
valve knob in the ON |
|
|
| ||||
|
| ||||||
|
|
|
|
| |||
|
| position? |
|
|
|
NO
Turn Unitrol gas knob to ON.
|
|
| Is the |
|
|
|
| NO |
|
|
|
|
|
|
| Thermostat |
|
|
|
| Contact a Qualified |
| |||||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
knob in the OFF |
|
|
|
|
| Technician. |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||||
|
| position? |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
YES
Turn Thermostat to a temperature setting.