INSTALLATION
5.When the pressure is correct, replace the regulator adjustment screw cover.
6.Turn off the ALL appliances, shut the main gas valve to your Pitco appliance and remove the pressure gauge. Apply pipe joint compound to the manifold pressure tap plug and reinstall it.
CAUTION
Be careful not to disturb the probe and high temperature limit during operation and cleaning of this appliance.
1.9. INITIAL CLEANING
When your appliance is shipped, many of its parts are covered with a thin coat of oil for protection. Before the appliance is ready for cooking it must be cleaned. This will remove the oil coating and any foreign matter that may have accumulated during storage and shipment. Refer to the following procedure to clean the appliance.
WARNING
Wear protective gloves and clothing when cleaning and draining the appliance and when disposing of water. The water is extremely hot and can cause severe injuries.
CAUTION
DO NOT leave the appliance unattended during cleaning. Never let the liquid level go below the heat tubes.
1.Read the “operation” section of this manual prior to filling or operating the appliance.
2.The following steps should be followed using a grease dissolving commercial cleaner.
WARNING
Use a commercial grade cleaner formulated to effectively clean and sanitize food contact surfaces. Read the directions and precautionary statements before use. Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food contact surfaces.
3.Following the manufacturer’s directions, clean the tank interior and all other food contact surfaces.
4.When cleaning is complete, rinse the inside of the tank thoroughly with cool water. Continue to rinse the tank until the cleaner has been completely and thoroughly rinsed from the tank.
5.Using a clean dry cloth, wipe out all of the water.
6.Repeat the previous steps to clean the bread and batter station or filter pan if equipped.