Note: This procedure requires the

SSPG14: Floor Model High Efficiency Gas Pasta Cooker

INSTALLATION

1.9.3.SELF CLEANING BURNER SYSTEM

The Self Cleaning Burner System (SCBS) is a self contained system inside your appliance which operates automatically once each time the appliance is turned “ON”.

The Pitco Self Cleaning Burner System is designed to help maintain proper operation and efficiency of your appliance’s combustion system by minimizing the build up of any foreign material inside the burner housings. Proper installation of this upgrade and periodic maintenance of the appliance are critical to safe, reliable and efficient operation.

1.9.4.PILOT FLAME ADJUSTMENT Perform this procedure with the pilot lit.

1.Connect the DC microampmeter between the Pilot flame sensor terminal (11) and the ignition wire (Not Shown). Observe proper polarity: if the meter needle goes below 0, reverse the leads. The current reading must be 1.0 A or greater, (0.15 A or greater for CE units).

2.If the current reading is below the required A level, the level can be increased by adjusting the pilot flame. Remove the pilot adjustment cap screw (6) to expose the pilot adjustment needle screw. Turn the needle screw counter clockwise (CCW) to increase the size of the pilot flame and flame sense current. Turning the pilot adjustment needle screw clockwise (CW) will decrease the pilot flame size and the flame sense current.

3.Rotate the screw in the direction needed to achieve a reading of 1.0 A or greater, (0.15 A or greater for CE units).

Note: Allow 3 to 5 minutes between flame adjustments to allow the reading to stabilize.

4.Once the pilot flame has been adjusted properly, replace the pilot adjustment screw cap screw and remove the microammeter.

Note: This procedure requires the

use of a DC microammeter.

FIGURE 2

L20-331, rev.02 (08/11)