Serial Port Settings and Diagnostics

Serial Port Settings and Diagnostics

If you want to control the displays remotely with RS232 commands from a computer, read this section. Otherwise, skip it.

Multiple displays can be linked together for RS232 control using a straight-through Ethernet cable. This is the common type of LAN connection cable sometimes called a Cat-5 cable. For more information, see "RS232 Communication" on page 21.

RS232 is also used to upgrade the firmware of the display.

Serial Port Settings

To access the SERIAL PORT SETTINGS menu, press MISC four times on the remote.

Serial Port Settings

Group ID

1

Unit ID

1

ASCII Response Type

Symbolic

ASCII Response Terminator

CR

Baud Rate

19200

 

 

Group ID and Unit ID

Each display in the loop must have a unique ID.

The RS232 ID has two parts, Group ID and Unit ID. Each part has a range of 0–9, A–Z. This range results in 1300 possible addresses.

You can group the displays by using the same letter or number of the Group ID, such as A. In this way you can address the group as A*, and all the displays in the string that have Group ID A and any Unit ID will execute the command.

Note: It does not matter what order you use to set IDs for the displays. It is common practice to use Unit IDs that are in order, left to right and top to bottom, but this is not mandatory. The only rule is: DO NOT USE THE SAME ID FOR DIFFERENT DISPLAYS.