| OFF | Disable port 6 Alarm |
6 |
|
|
ON | Enable port 6 Alarm. If the port’s link fails, the fault LED will | |
| light up. | |
|
| |
|
|
|
| OFF | Disable port 7 Alarm |
7 |
|
|
ON | Enable port 7 Alarm. If the port’s link fails, the fault LED will | |
| light up. | |
|
| |
|
|
|
| OFF | Disable port 8 Alarm |
8 |
|
|
ON | Enable port 8 Alarm. If the port’s link fails, the fault LED will | |
| light up. | |
|
| |
|
|
|
| OFF | Disable the ring master function. |
9 |
|
|
ON | Enable the switch as the ring master in the redundant ring | |
| group. | |
|
| |
|
|
|
[NOTE]
1.When port alarm function is enabled, the fault LED will on and Alarm relay will activity when port failure occurs.
2.Please restart the switch after the Redundant ring DIPswitch is set.
2.1.6 Switch Bottom Panel
The bottom panel of the
Figure
Figure
2.1.7 Wiring the Power Inputs
Please follow below steps to insert the power wire.