Alert Messages

The following Notifications and Warnings are sent by the controller.

Notifications

Normal operation of power supply in slot <number> restored

Normal operation of fan in slot <number> restored

The temperature in the system is now within the acceptable range

Creating RAID ‘<name>’, useable capacity: <capacity> GB

RAID ‘<name>’ is now accessible

Initialising RAID ‘<name>’

Initialisation of RAID ‘<name>’ deferred for a higher priority RAID

RAID ‘<name>’ initialisation complete

Deleting RAID ‘<name>’

Expanding RAID ‘<name>’ by adding rows

Expanding RAID ‘<name>’ by adding <number of columns> column(s)

Initialising expansion space on RAID ‘<name>’

RAID ‘<name>’ expand complete

Rebuilding RAID ‘<name>’

Rebuild of RAID ‘<name>’ deferred for a higher priority RAID

RAID ‘<name>’ rebuild complete

Disk in bay <number> is no longer part of RAID ‘<name>’

Verifying RAID ‘<name>’

Verification of RAID ‘<name>’ deferred for a higher priority RAID

RAID ‘<name>’ verification complete

Logical volume '<name>' created

Logical volume '<name>' deleted

Logical volume '<name>' capacity expanded to <capacity>

Logical volume '<name>' ID:LUN changed to <SCSI ID>:<LUN>

Logical volume '<name>' changed to '<new name>'

Starting Firmware <version> (<build time and date>) reboot <reboot count>

Network up at IP address <IP address>, netmask <netmask>

Password has changed

Fibre Channel Port <port> is up at <speed> Gb in <fibre channel mode> mode

Warnings

Disk in bay <number> is missing

Disk in bay <number> has excessive errors

Disk in bay <number> is running out of reallocation blocks

Disk in bay <number> has run out of reallocation blocks

Disk in bay <number> has failed

Power Supply Module in slot <number> is not working properly

Fan in slot <number> is not working properly

The temperature in the system has exceeded <threshold value> threshold

The temperature in the system has dropped below 10C/50F

RAID ‘<name>’ initialisation failed to complete

RAID ‘<name>’ verify failed to complete

RAID ‘<name>’ expand failed to complete

RAID ‘<name>’ rebuild failed to complete

RAID ‘<name>’ is degraded due to disk failures

RAID ‘<name>’ is inaccessible due to disk failures

RAID ‘<name>’ has no suitable spare available

Cannot start scheduled verify on RAID ‘<name>’

Controller hardware error

Firmware download checksum failed, the binary may be corrupted

Firmware ID does not match, the binary is not for this product

Raidtec FS3102 Hardware Installation Guide

Version 1.0

26

Page 26
Image 26
Plasmon FS3102 manual Alert Messages, Notifications