The SCSI bus must also be terminated at the host adapter end. Normally, the termination function is built into the host adapter.

TERMINATOR

EP006089

Host-to-LF 6602 Daisy Chain Cable Connections

A terminator must always be installed on the vacant connector of the last SCSI device in the SCSI bus. The SCSI bus must always be terminated externally on the rear panel of an LF 6600 when an LF 6602 is the last SCSI device on the bus.

NOTE

You must first determine the type of termination your host system requires (see the Accessories section of this manual).

In a daisy chain configuration, a terminator must be used on both the first and last devices on the bus. One of these devices may be the host adapter.

All other LF 6602's between the first and last device in the daisy chain should not be terminated.

NOTE

Installation of both an active single-ended terminator and a passive single-ended terminator on the same bus is not recommended.

If only one LF 6602 is attached to a host, the bus must be terminated at the host adapter and the LF 6602 host computer (refer to the next figure).