MULTIPLE-DEVICE CONFIGURATION

To connect SCSI cables and a terminator, if necessary, in a multiple LF 6602 configuration, refer to the Single Device Configuration section and connect the SCSI cables according to steps 1 through 3).

If the LF 6602 is part of a daisy chain configuration and is not the last unit in the chain, install one end of a SCSI interface cable into the lower connector of the second drive and then install the other end of the cable into the connector of the next device in the chain. Repeat this process until you reach the last SCSI device in the daisy chain.

A terminator must be installed on the second drive's lower connector of the last LF 6602 in a daisy chain.

The SCSI bus must also be terminated at the host adapter when the host occupies the last position on the bus.

Power for the external terminators can also be supplied by either drive in the LF 6602 cabinet or another device in the SCSI daisy chain. It is very important that the SCSI bus is terminated at both ends in accordance with the LD 6100/LF 6600/LF 6602 SCSI Specification (P/N 97653978).

CONNECTOR VERIFICATION

Prior to powering on the system:

1)Verify proper termination at the host adapter, if applicable.

2)Verify proper termination at the last LF 6602 on the bus, if applicable.

CAUTION

Ensure that the foam shipping blocks have been removed from the shuttle assemblies before powering on the drives.

Refer to the Operating Instruction section in this manual for the power-on procedure.

97654438 E Page 39