INSPECTING AND CLEANING FAN AND BLOWER FILTERS

Two filters located on the drive's rear panel remove contaminants from air pulled into the drive (see figure below).

FILTER ELEMENT

OUTER FAN

GRIL HALF

EP006088

Removing Filter Element from Fan

Inspect the Filters at the rear of the drive on a 1 - 6 month schedule and clean, if necessary, to ensure that cooling air flow is not restricted. If the drive is exposed to excessive amounts of dust, decrease the time between inspection intervals.

Remove dust on the drive's exterior with a dry, lint-free cloth. Dust can migrate to the media cartridge and cause performance degradation.

CAUTION

Failure to maintain a clean Filter Element can reduce air flow through the drive. This will create high temperatures in each LF 6600 which may shorten the life of the drive.