Before Starting
Risk of Unsafe Operation. Serious damage may result if the following
followed.
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1.Make sure the On/Auto/Off lever is in the "OFF" position.
2.Check oil level in pump. See “Oil” paragraph in the “Maintenance” section for instructions.
3.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)
4.Open the drain valve fully
5.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.
6.Run the compressor for 20 minutes. Make sure the drain valve is open and there is minimal air pressure
7.After 20 minutes, close the drain valve (clockwise). The air receiver will fill to
The compressor is now ready for use.
Before Each Start-Up:
1.Place On/Auto/Off lever to “OFF”.
2.Pull regulator knob out, turn
3.Attach hose and accessories.
Risk of Flying Objects. Pull the regulator knob out and turn
removing hose or accessories to prevent hose backlash.
NOTE: The hose or accessory will require a quick connect plug. To use remote console, see "How to Use Remote Console" paragraph in this section.
Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s
maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
D28301 | 14- ENG |