| PROBLEM | CAUSE |
| CORRECTION | ||||
| Excessive tank | Pressure switch does not | Move On/Auto/Off lever to | |||||
| pressure - | shut off motor when | the “OFF” position, if the | |||||
| safety valve | compressor reaches “cut- | outfit does | |||||
| pops off. | out” pressure. | not shut off contact a | |||||
|
|
| Trained Service Technician. | |||||
|
| Pressure switch | Contact a Trained Service | |||||
|
| too high. | Technician. | |||||
|
|
|
|
|
|
|
|
|
| Air leaks at | Tube fittings are not tight | Tighten fittings where air can | |||||
| fittings. | enough. | be heard escaping. Check | |||||
|
|
| fittings with soapy water | |||||
|
|
| solution. DO NOT | |||||
|
|
| OVERTIGHTEN. | |||||
|
|
|
|
| ||||
| Air leaks at or | Check valve seat damaged. |
| A defective check valve | ||||
| inside check |
|
| results in a constant air leak | ||||
| valve |
|
| at the pressure release valve | ||||
|
|
|
| when there is pressure in the | ||||
|
|
|
| tank and the compressor is | ||||
|
|
|
| shut off. Replace check | ||||
|
|
|
| valve. Refer the “To Replace | ||||
|
|
|
| or Clean Check Valve” in the | ||||
|
|
|
| “Service and Adjustment” | ||||
|
|
|
| section. | ||||
|
|
|
|
|
|
|
|
|
| Air leaks at | Defective pressure switch | Contact a Trained Service | |||||
| pressure switch | release valve. | Technician. | |||||
| release valve. |
|
|
|
|
|
|
|
| (if equipped) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Air leaks in air | Defective air tank. | Air tank must be replaced. | |||||
| tank or at air |
| Do not repair the leak. | |||||
| tank welds. |
|
|
|
|
| Risk of | |
|
|
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
|
|
| Bursting. | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
| Do not drill into, weld or | |||||
|
|
| otherwise modify air tank | |||||
|
|
| or it will weaken. The tank | |||||
|
|
| can rupture or explode. | |||||
| Air leaks | Leaking seal. | Contact a Trained Service | |||||
| between head |
| Technician. | |||||
| and valve plate. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|