Porter-Cable C6110 Service and Adjustments, Air Compressor Pump Intake and Exhaust Valves

Models: C6110

1 72
Download 72 pages 63.66 Kb
Page 15
Image 15

If it is dirty, replace it with a new filter.

1.Using a pair of needle nose pliers or a screwdriver pull or pry out the old filter and carefully clean the filter area.

2.Push the new air filter in place.

Air Compressor Pump Intake and Exhaust Valves

Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves.

SERVICE AND ADJUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

To Replace or Clean Check Valve

 

 

 

 

 

 

1.

Release all air pressure from air tank. See To

 

Outlet

 

 

Tube

 

 

Drain Tank in the Maintenance section.

 

 

 

 

 

 

2.

Unplug air compressor.

 

 

 

3.

Using an adjustable wrench loosen outlet

 

Nut

 

tube nut at air tank and pump. Carefully

 

 

 

 

move outlet tube up away from check

 

Check

 

valve.

 

 

 

Valve

4.

Using an adjustable wrench loosen pressure

 

 

 

 

 

relief tube nut at air tank. Carefully move

 

 

 

 

pressure relief tube away from check valve.

 

 

 

5.Unscrew the check valve (turn Pressure

counterclockwise) using a 7/8" open

Relief

Nut

end wrench. Note the orientation for

Tube

reassembly.

 

 

 

 

6.Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve

disc should move freely up and down on a spring which holds the valve

disc in the closed position, if not the

Screwdriver

check valve needs to be cleaned or

In open

replaced.

position

7. Clean or replace the check valve.

nothing is

A solvent, such as paint or varnish

visible.

remover can be used to clean the

In closed position

check valve.

disc is visible.

8.Apply sealant to the check valve

threads. Reinstall the check valve (turn clockwise).

9.Replace the pressure release tube. Tighten nut.

10.Replace the outlet tube and tighten nuts.

15-­ ENG

Page 15
Image 15
Porter-Cable C6110 Service and Adjustments, Air Compressor Pump Intake and Exhaust Valves, To Replace or Clean Check Valve