To Replace Regulator

1.Release all air pressure from air tank. See To Drain Tank in the Maintenance section.

2.Set the Auto/Off lever to "Off" and unplug unit.

3.Using an adjustable wrench remove the outlet pressure gauge and quick con- nect from the regulator.

4.Using an adjustable wrench loosen pressure relief tube nut at air tank. Carefully move pressure relief tube away from check valve.

Outlet Pressure

Gauge

Quick

Connect

Regulator

Pressure

Relief Tube

Nipple

Regulator

5.Remove the regulator.

6.Apply pipe sealant tape to the nipple on the standpipe.

7.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

8.Reapply pipe sealant to outlet pressure gauge and quick connect.

9.Reassemble outlet pressure gauge, pressure relief tube and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

Regulator

Arrow

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary.

2.Drain water from air tank. See To Drain Tank under Maintenance.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

3.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle.

4.Store the air compressor in a clean and dry location.

16- ENG­

Page 16
Image 16
Porter-Cable C6110 instruction manual Storage, To Replace Regulator