PROBLEM

CAUSE

CORRECTION

Motor will

Motor overload protection

Refer to Motor Overload Protection

not run

switch has tripped.

under Operation. If motor overload

 

 

protection trips frequently, contact

 

 

a Trained Service Technician

 

Tank pressure exceeds

Motor will start automatically when

 

pressure switch

tank pressure drops below "cut-

 

"cut-in" pressure.

in" pressure of pressure switch.

 

Check valve stuck open.

Remove and clean, or replace.

 

Loose electrical

Check wiring connection inside

 

connections.

pressure switch and terminal box area.

 

Possible defective motor

Have checked by a Trained

 

or starting capacitor.

Service Technician.

 

Paint spray on internal

Have checked by a Trained Service

 

motor parts.

Technician. Do not operate the

 

 

compressor in the paint spray area.

 

 

See flammable vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch to

 

unloaded head pressure.

the "Off" position; if the valve

 

 

does not open, replace switch.

 

Fuse blown, circuit

1. Check fuse box for blown fuse

 

breaker tripped.

and replace as necessary. Reset

 

 

circuit breaker. Do not use a fuse

 

 

or circuit breaker with higher

 

 

rating than that specified for

 

 

your particular branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay fuse.

 

 

3. Check for low voltage conditions

 

 

and/or proper extension cord.

 

 

4. Disconnect the other electrical

 

 

appliances from circuit or

 

 

operate the compressor on

 

 

its own branch circuit.

Knocking Noise

Possible defect in

Operate safety valve manually

 

safety valve.

by pulling on ring. If valve still

 

 

leaks, it should be replaced.

 

Defective check valve.

Remove and clean, or replace.

LIMITED Warranty

PORTER-CABLE industrial tools are warranted from date of purchase, as follows:

3 YEAR – Limited warranty on 2-stage oil-free air compressor pumps operating at 1725 RPM.

2 YEAR – Limited warranty on oil-lubricated air compressor pumps.

1 YEAR – Limited warranty on all other air compressor components.

PORTER-CABLE will repair or replace, without charge, at PORTER-CABLE’s option, any defects due to faulty materials or workmanship. For further detail of warranty coverage and warranty repair information, call 1-(888)-8485175 or visit deltaport- ercable.com. This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty also does not apply to merchandise sold by PORTER-CABLE which has been manufactured by and identified as the product of another company, such as gasoline engines.

19-­ ENG

Page 19
Image 19
Porter-Cable C6110 instruction manual Limited Warranty, Refer to Motor Overload Protection