PROBLEM

CAUSE

 

CORRECTION

 

 

 

 

Air compressor

Air compressor overworked.

 

Reduce air consumption or add

overheating.

 

 

another air compressor to take up

 

 

 

some of the load.

 

The outlet tube and/or check

 

Check the tube and the check

 

valve is restricted.

 

valve. Clean if necessary.

 

Dirty air compressor.

 

Clean the air compressor

 

 

 

thoroughly.

 

High ambient temperature.

 

Use remote air intake.

 

 

 

 

Motor overheating.

Incorrect oil, low oil.

 

See oil recommendation on page

 

 

 

15.

 

Low voltage.

 

Provide correct voltage. Consult

 

 

 

local power company or electrician.

 

Pressure switch set beyond

 

Do not set switch beyond maximum

 

factory setting.

 

for which unit was designed as

 

 

 

noted on nameplate.

 

Belt too tight.

 

Adjust for proper tension.

 

Air compressor valves have

 

Clean or replace air compressor

 

excessive carbon deposits

 

valves or check valve.

 

build-up; restricted check valve.

 

 

Too many motor starts per hour.

 

Consult Service Center.

 

Improper wiring gauge.

 

Check electrical hookup and

 

Incorrect voltage.

 

installation data or consult

 

 

electrician.

 

 

 

 

 

NOTE

 

Current style electric motors run relatively hot under normal operating

 

conditions, with reasonable air compressor loading. This condition is

 

normal and no adjustment is necessary.

 

Under normal operating conditions, the motor amperage draw will

 

not exceed the nameplate amperage rating, plus the service factor, as

 

it appears on the electric motor. If a condition of sustained high

 

amperage exists, refer to service checks above and/or consult

 

electrician. If cause cannot be isolated by an electrician, consult with

 

Service Center for additional assistance.

 

 

 

 

Water in pump

Humid operating conditions.

 

Relocate air compressor unit, or

crankcase; oil

 

 

change oil frequently.

appears milky in

 

 

 

color.

Unit not reaching proper

 

Consult Service Center.

 

 

 

operating temperature because

 

 

 

the air compressor runs

 

 

 

infrequently and is oversized for

 

 

 

the air requirement.

 

 

 

 

 

 

Liquid water or

Condensation forms in air lines

 

Install compressed air dryer sized

moisture in air lines.

when the warm compressed air

 

for the flow and dryness level

 

coming from the air tank starts

 

required.

 

to cool down as it travels

 

 

 

through the air lines.

 

 

 

 

 

 