Air Intake Filter (not shown) This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstruc- tions. See "Maintenance".

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to “OFF”.

Before Starting

Break-in Procedure

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

2.Recheck all wiring. Make sure wires are secure at all terminals connections. Make sure all contacts move freely and are not obstructed.

3.Open the globe valve fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.

5.Run the compressor for 30 minutes. Make sure the globe valve is open and there is minimal air pressure build-up in tank.

6.Check all air line fittings and connections/piping for air leaks by applying a soap solution. Correct if necessary. NOTE: Minor leaks can cause the air com- pressor to overwork, resulting in premature breakdown or inadequate perform- ance.

7.Check for excessive vibration. Readjust or shim air compressor feet, if neces- sary.

8.After 30 minutes, move the On/Auto/Off lever to "OFF" position and close the globe valve.

9.Move the On/Auto/Off lever to "ON/AUTO" position. The air receiver will fill to “cut-out” pressure and the motor will stop.

Before Each Start-Up:

1.Place On/Auto/Off lever to “OFF”.

2.Close the globe valve.

3.Attach hose and accessories. NOTE: A regulator MUST be installed when using accessories rated at less than 110 PSI.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pres-

sure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start

1.Turn the On/Auto/Off lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.

2.When the tank pressure reaches “cut-out” pressure open the globe valve.

IMPORTANT: When using regulator and other accessories refer to the manufactur- er-s instructions.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer, DO NOT place compressor near the spray area.