SERVICE AND ADJUSTMENTS

Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, com- pressed air or moving parts. Personal injuries can occur.

Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Before servicing:

Unplug or disconnect electrical supply to the air compressor. Bleed tank of pressure.

Allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section.

2.Unplug unit.

3.Using an adjustable wrench loosen

outlet tube nut at air tank and pump.

 

Carefully move outlet tube away from

Nut

check valve.

 

4.Using an adjustable wrench loosen

pressure relief tube nut at air tank and

 

Outlet Tube

 

 

 

 

pressure switch. Carefully move pres-

 

Check

sure relief tube away from check valve.

 

Valve

5. Unscrew the check valve (turn coun-

Pressure

Relief Tube

terclockwise) using a 7/8” open end

 

 

 

wrench. Note the orientation for

 

 

 

reassembly.

 

 

Nut

6. Using a screwdriver, carefully push the

 

 

 

 

 

valve disc up and down. NOTE: The

Nuts

valve disc should move freely up and

 

 

 

down on a spring which holds the

 

 

 

valve disc in the closed position, if not

 

 

 

 

the check valve needs to be cleaned or replaced.

 

 

 

 

 

 

7. Clean or replace the check valve. A solvent, such

 

 

 

as paint or varnish remover can be used to clean

 

 

 

the check valve.

 

Screwdriver

 

 

 

8.Apply sealant to the check valve threads.

Reinstall the check valve (turn clockwise).

In open position nothing is visible.

9.Replace the pressure release tube. Tighten nuts.

10. Replace the outlet tube and tighten nuts.

11.Perform the Break-in Procedure. See “Break-in Procedure” in the Operation section.

In closed position disc is visible.