PROBLEM | CAUSE | CORRECTION |
|
|
|
Air leak from | Possible defect in | Operate safety valve |
safety valve. | safety valve. | manually by pulling on |
|
| ring. If valve still leaks, |
|
| it should be replaced. |
|
|
|
Knocking Noise. | Possible defect in | Operate safety valve |
| safety valve. | manually by pulling on |
|
| ring. If valve still leaks, |
|
| it should be replaced. |
|
|
|
Pressure reading on | It is normal for "some" | If there is an excessive |
the regulated pressure | pressure drop to occur. | amount of pressure drop |
gauge drops when an |
| when the accessory |
accessory is used. |
| is used, adjust the |
|
| regulator following |
|
| the instructions in |
|
| the Description of |
|
| Operation paragraph in |
|
| the Operation Section. |
|
| NOTE: Adjust the |
|
| regulated pressure |
|
| under flow conditions |
|
| (while accessory |
|
| is being used). |
|
|
|
Compressor is not | Prolonged excessive | Decrease amount |
supplying enough air to | use of air. | of air usage. |
operate accessories. | Compressor is not | Check the accessory |
| ||
| large enough for | air requirement. If |
| air requirement. | it is higher than the |
|
| SCFM or pressure |
|
| supplied by your air |
|
| compressor, you need |
|
| a larger compressor. |
| Hole in hose. | Check and replace |
|
| if required. |
| Check valve restricted. | Contact a Trained |
|
| Service Technician |
| Air leaks. | Tighten fittings. |
|
|
|
Regulator knob has | Damaged regulator. | Replace. |
continuous air leak. |
|
|
|
|
|
Regulator will not | Damaged regulator. | Replace. |
shut off air outlet. |
|
|
|
|
|
16 - ENG