OPERATION

KNOW YOUR GENERATOR

Read this General Manual and Safety Rules before operation of your Generator. Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and adjustments. Save all manuals for future references.

GENERATOR CAPACITY

IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage to your generator and connected electrical devices. See the Wattage Calculation section in this manual to assist you in determining the appliances and tools that can be run with the wattage capacity of your generator.

CIRCUIT BREAKERS

Each receptacle has a circuit breaker to protect the generator from overloading. If the circuit breaker trips, unplug all electrical loads from the generator. Let the circuit breaker cool down. Push circuit breaker button to reset.

LOW OIL PROTECTION

Your generator engine is equipped with Low Oil Shutdown. Low Oil Shutdown is a safety device designed to protect your engine from damage in the event the oil level in the crankcase is low.

If while the engine is running, the oil gets low, it will automatically shut itself down and will not restart until the oil is added. If the oil is low before start-up, the generator will not start until oil is added.

NOTE: The Low Oil Shutdown mechanism is very sensitive. You must fill the engine to the full mark on the dipstick to inactivate this safety device.

BEFORE START UP

This generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

Always check engine oil level before every start. Running engine low of oil or out of oil could result in serious damage to the engine.

Follow the steps listed below before starting generator:

1. Check engine oil. Refer to the Engine Operator's Manual for correct grade and quantity of oil.

2.Check fuel level, fill as required. Make sure generator is turned

off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline.

Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel

spillage from engine and equipment before starting engine.

Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.

Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly

gas.

3.Make sure generator is grounded in accordance with local requirements.

4.All electrical loads MUST be disconnected.

Engine speed has been factory set to provide safe operation.

D28733

12- ENG

Page 12
Image 12
Porter-Cable PGN350, D28733-034-0 instruction manual Operation

D28733-034-0, PGN350 specifications

The Porter-Cable D28733-034-0, PGN350 is a versatile and robust tool designed for professionals and DIY enthusiasts who demand high-performance tools in their projects. This pneumatic nail gun is engineered for reliability and precision, making it a popular choice in the construction and woodworking industries.

One of the main features of the PGN350 is its lightweight design, which enhances portability and ease of use. Weighing in at just a few pounds, operators can maneuver this tool comfortably for extended periods, reducing fatigue during long job sessions. Additionally, its durable construction ensures it can withstand the rigors of job site conditions.

Equipped with a powerful motor, the PGN350 delivers exceptional driving force, allowing it to effortlessly handle a range of fasteners, including 1-1/4 inch to 3-1/2 inch collated framing nails. This versatility makes it suitable for various applications, including framing, decking, and other structural tasks. The tool’s depth adjustment feature provides improved control over nail depth, ensuring a professional finish even on varying materials.

The PGN350 incorporates advanced technologies that enhance user experience and performance. Its rapid-fire mode allows for quick and efficient nailing, which is an essential feature for projects requiring high productivity. Moreover, the tool is designed with a tool-free jam release mechanism, making it easy to clear nail jams without the need for additional tools, thus minimizing downtime.

Safety is also a priority with the PGN350. It comes equipped with a trigger lock-off feature, which prevents accidental firing, offering peace of mind when the tool is not in use. This safety mechanism is fundamental for maintaining workplace safety, particularly in busy construction environments.

The unit features a comfortable grip and an ergonomic design that provides stability and control, reducing the risk of wrist strain and enhancing overall efficiency. The tool's air inlet is compatible with standard air hoses, making it easy to integrate into existing pneumatic tool systems.

In summary, the Porter-Cable D28733-034-0, PGN350 stands out for its lightweight design, powerful performance, and user-friendly features. Its advanced technologies, safety mechanisms, and versatility make it an essential tool for anyone looking to accomplish professional-grade results in their woodworking or construction projects. Whether you are framing a house or building furniture, the PGN350 is built to deliver reliability and precision every time.