POSIFLEX Business Machines 16560900020 user manual Connecting Cash Drawer Option, Desktop Mounting

Models: 16560900020

1 20
Download 20 pages 6.59 Kb
Page 12
Image 12
CONNECTING CASH DRAWER (OPTION)

the DC supply in COM port is not required, it will be powered through the USB port.

CONNECTING CASH DRAWER (OPTION)

The RJ11 connector in main connection area of a KS system can be used for controlling most of the common cash drawers available on the market. However, it is most recommended that the Posiflex CR-2000 or CR-2200 or CR-3100 or CR-3200 or CR-4000 or CR-4100 or CR-4210 or CR-6210 be used for best compliance.

The KS system will directly control the cash drawer using the cash drawer port (CR) both to operate the opening mechanism and to monitor the drawer open status. Both functions may be accomplished under software control of the COM1 serial port.

Use the cable supplied with the cash drawer (Part No. 21863018010) for connection to the CR port in KS system. This cable has a 6-pole plug at one end and an 8-pole plug at the other. The 8-pole plug should be inserted into the connector marked: “signal cable from POS Printer” at the rear of the cash drawer. The 6-pole plug should be inserted in the connector marked “CR” found in the main connection area in the system.

The user may also use the optional 2-in-1 cash drawer control cable CCBLA-238 to control 2 cash drawers in 1 port. It has a 6-pole plug at one end and two 8-pole plugs at the other. The 6-pole plug should be inserted in the connector marked “CR” found in the main connection area in the system. Each 8-pole plug should be inserted into the connector marked “signal cable from POS Printer” at the rear of one of the cash drawers. The cable lengths for the two 8-pole plugs are different. Use the shorter one for the original cash drawer “CR1” and use the longer one for the extended cash drawer “CR2” that will be distinguished by the software command.

DESKTOP MOUNTING

Matching Pegs

Round Part

Gen 5 base

Gen 6 base

Slot Part

Match the matching pegs on the back of the main unit against the (rectangular marked above for both base types) matching holes on the stand assembly. First aim the matching pegs toward the upper round part of the hole (ref. the close-up illustration) and make sure that all pegs are inside the holes.

Part 12