Part 10
WALL MOUNTING
The major part in the wall mounting kit is a bracket as shown in the
picture. Screw the bracket against the wall for mounting the Jiva TP/LT-
5700G / Jiva TP/LT-5800G in the direction that the wider parts of the
matching holes are at the top as shown in the picture below. Align the four
matching pegs on the back of the main unit with the four matching holes in the
bracket to hold the main unit in the similar manner as installing the main unit
onto the stand assembly. The stand assembly is not engaged in wall mount
operation.
LOCATION FOR INSTALLATION
As the stand assembly is not involved in wall mount installation, the
space required for wall mount application will take only the main unit into
consideration. So the space required is 375 mm in width and 315 mm in height.
For desk top/counter application, the adjustable stand assembly
requires a base of 270 mm deep and 260 mm wide. However, please take also
the main unit into consideration. If the main unit is tilted to near vertical
position, the total height is 360 mm. When the main unit is tilted to near
horizontal position, the total height required is 275 mm.
OPERATING SYSTEM RECOVERY
For Jiva TP/LT-5700G, if not using a remote boot operating system,
the operating system exists in the Compact Flash Card. Therefore, once the
Compact Flash is damaged for any reason, the thin client may fail to boot. A
bootable new Compact Flash Card will be required to have the
workstation back to work. Please follow instructions given by the System
Integrator to deal with situations like that. One more advice for CF Card
application is that in spite of the fact that it is used in the way like an ordinary
HDD, usual system management utilities such as FDISK.EXE or
FORMAT.COM shall never be used on CF Card otherwise the boot sector
of operating system itself may be damaged and causing the CF Card no longer
bootable.
For Jiva TP/LT-5800G, the operating system exists in the HDD. Once
Matching Holes
Screw
Holes
Wall Mount Bracket
Show
this
side
out.