B. SETUP WINDOW

On bottom cover of the Aura series thermal printer, there is screwed a metal plate for setup window. In this window, there is a 8 position DIP switch for printer setup. Please use proper tool to change the switch setting when necessary. The switch position counting starts from the nearest edge of printer. The ON direction points to the connector area of the printer. The OFF direction points to the power switch. The functions of each position may evolve with the revisions of the firmware. The information below applies to the latest version to the date of print of this manual.

This 8 position DIP switch works as following:

Switch

ON

OFF

position

 

 

1

RS232 baud rate definition or Parallel interface

2

definition (ref. separate table below)

3

Even parity

None parity

4

XON handshaking

Hardware handshaking

5

Busy on “buffer full”

Busy on “off line”

6

Immediate cut

Protective cut

7

CR code effective

CR code ineffective

8

Factory internal setting

Application standard mode

Effect of positions 1 & 2 on baud rate is defined as in table below with parity check set according to position 3, number of data bits always set to 8, and stop bit set to 1. When the parallel interface is used, please set both positions to ON.

SW Pos. 1

ON

OFF

ON

OFF

SW Pos. 2

ON

ON

OFF

OFF

Baud rate

38400 bps /

4800 bps

9600 bps

19200 bps

or Interface

(Parallel)

 

 

 

Switch position 3 defines the parity check regulation in serial interface. In Aura, it is selectable between even and none.

5 - 2