JUMPER SETTING

POSITIONFUNCTIONJUMPER SHORTJUMPER OPENJP183 STATUSJP184 STATUSManual backgroundManual backgroundManual background TM

JUMPER SETTING

POSITION

FUNCTION

JUMPER SHORT

JUMPER OPEN

J10

JIS II/ISO

JIS II MSR

ISO MSR

J13

ALT + NUM

OFF

ON

J14

TRACK 1

ON

OFF

J15

TRACK 3

ON

OFF

J16

TRACK 2

ON

OFF

J17

Leading & ending sentinel

OFF

ON

JP183 STATUS

JP184 STATUS

FUNCTION

1-2, 3-4, 5-6, 7-8 short

All open

MSR enabled

All open

1-2, 3-4 short

MSR disabled