OPERATING VOLTAGE

CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.

A power line conditioner should be used when running one or more of the following solid state items:

Garage door openers

Kitchen appliances with digital displays

Televisions

Stereos

Personal computers

Quartz clocks

Copy machines

Telephone equipment

Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805.

INSTALLATION

To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.

To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.

If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.

Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.

To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.

Always follow local codes and regulations that apply to the installation of any item that concerns this product.

1.NFPA 70 - National Electrical Code.

2.NFPA 37 - Standard for Installation and Use of Stationary Combustible Engines.

3.Agricultural Wiring handbook of Farm Standby Electric Power.

English

 

5

 

Customer Hotline 1-800-445-1805

 

 

 

 

 

Page 5
Image 5
Powermate PM0103000 manual Operating Voltage, Installation

PM0103000 specifications

The Powermate PM0103000 is a powerful and versatile generator designed to meet the needs of both residential and commercial users. It is particularly popular among construction sites, outdoor events, and emergency situations, providing reliable electricity when it is needed most. One of its standout features is its robust engine, which is engineered for efficiency and longevity. With a potent 10,000 watt peak output and a continuous output of 8,000 watts, the PM0103000 delivers ample power to run multiple appliances simultaneously, making it ideal for heavy-duty applications.

Equipped with a 420cc four-stroke engine, this generator ensures reliable performance and low fuel consumption. It runs on gasoline, providing convenience and ease of use for a variety of settings. The generator includes a large fuel tank that offers extended run time, allowing users to focus on their tasks without frequent refueling interruptions. Additionally, the Powermate PM0103000 features a low-oil shutdown system, which helps protect the engine from damage by automatically turning off the generator when oil levels are too low.

Durability is another key characteristic of the PM0103000. It boasts a rugged steel frame that not only protects the generator components but also enhances its stability during operation. The generator is fitted with pneumatic tires, allowing for easy maneuverability across different terrains. Users will also appreciate the built-in transport handle, which provides added convenience for mobility.

In terms of technology, the PM0103000 incorporates an advanced voltage regulator, offering stable power output to protect sensitive electronics from voltage fluctuations. The inclusion of multiple outlets enhances its functionality, providing several 120V AC outlets as well as a 12V DC outlet for battery charging.

Noise reduction is an essential feature for many users, and Powermate has taken this into account with the design of the PM0103000. The generator is engineered to operate at relatively low noise levels compared to other models in its class, making it suitable for use in residential areas or during outdoor gatherings where noise may be a concern.

In summary, the Powermate PM0103000 generator combines powerful performance with user-friendly features and rugged durability. Its efficient engine, ample power output, advanced voltage regulation, and low noise operation make it an excellent choice for anyone in need of reliable energy in various settings. Whether for emergency preparedness or daily use, the PM0103000 shines as a dependable power solution.