EXCITING THE GENERATOR:

some time, it is a good idea to drain the fuel from the

 

If there is a loss of residual magnetism (voltage will not

carburetor and gas tank.

build up), it may be necessary to re-excite the unit.

LONG TERM STORAGE

1.

Use a 6-volt lantern battery (dry cell) or a 12-volt

 

automotive battery.

 

When the generator set is not being operated or is being

2.

Disconnect all loads from generator.

stored more than one month, follow these instructions:

3.

Remove the brush cover.

1.

Replenish engine oil to upper level.

4.

Plug a lamp or light into the generator before starting the

2.

Drain gasoline from fuel tank, fuel line and carburetor.

 

engine. The light source will illuminate when voltage has

3.

Pour about one teaspoon of engine oil through the spark

 

returned.

 

plug hole, pull the recoil starter several times and replace

5.

Start the engine with no load connected to the generator.

 

the plug. Then pull the starter until you feel the piston is

6.

Attach the "-" lead of the battery to the negative brush.

 

on its compression stroke and leave it in that position.

 

Very briefly, touch the "+" lead of the battery to the

 

This closes both the intake and exhaust valves to prevent

 

positive brush as shown. Remove as soon as voltage

 

the inside of the cylinder from rusting.

 

builds up. To measure voltage, use a plug-in voltmeter.

4.

Cover the unit and store in a clean, dry place that is well

 

 

 

ventilated away from open flame or sparks.

NOTE: We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

SERVICE INFORMATION

HEAT SHIELD:

Inspect to ensure that all heat shields and heat deflectors are intact and in place. Do not remove any parts or modify parts. Removing or modifying parts could cause serious damage to the unit.

ENGINE: Carburetor Icing

During the winter months, rare atmospheric conditions may develop which will cause an icing condition in the carburetor. If this develops, the engine may run rough, loose power, and may stall. Call Product Service for more information.

NOTE: Refer to the engine manufacturer's manual for service and maintenance of the engine.

QUICK STARTING TIPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE:

If your unit has been sitting around for a long time period and is hard to start, try doing some of these easy steps before calling the Customer Hotline.

1.Check the oil level.

2.Replace the old fuel.

3.Change the spark plug.

4.Check the fuel lines. Make sure the fuel valve is open.

5.Check all generator parts for integrity.

6.Clean the Carburetor. (See engine manual for service centers)

SERVICE AND STORAGE

INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may result. to eliminate hard starting, run the generator at least 30 minutes every month. Also, if the unit will not be used for

CONTACT THE

COLEMAN® POWERMATE®

PRODUCT SERVICE DEPARTMENT AT

1-800-445-1805 or at www.powermate.com

to obtain warranty service information or to

order replacement parts or accessories

HOW TO ORDER REPLACEMENT PARTS

Even quality built equipment such as the Coleman® Powermate® electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the fol- lowing information:

1.Model No. and Serial No. and all specifications shown on the Model No./Serial No. plate.

2.Part number or numbers as shown in the Parts List section.

3.A brief description of the trouble with the generator.

NOTE: If replacement parts are required for the engine, contact one of the engine manufacturer's service centers.

Powermate Corporation

4970 Airport Road

P. O. Box 6001

Kearney, NE 68848

1-800-445-1805

www.powermate.com

www.powermate.com

 

12

 

Customer Hotline 1-800-445-1805

 

 

 

 

 

Page 12
Image 12
Powermate PM0647001 manual Service Information, Service and Storage