Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.
Make sure the voltage of your power supply matches the specifications on the motor plate of the Band Saw. The machine should be connected to a dedicated circuit, and protected by a circuit breaker or time delay fuse, with minimum amp ratings as shown in Table 1. Local codes take
precedence over recommendations.
Extension cords
The use of an extension cord is not recommended for the 2013 or 2415 Band Saw. But if one is necessary, make sure the cord rating is suitable for the amperage listed on the machine’s motor plate. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
Use the chart in Figure 7 as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
230 Volt, Single Phase Operation
As received from the factory, the
If connecting a plug, use a proper UL/CSA listed 2- pole,
If the Band Saw is to be
230 Volt, Three Phase Operation
The
| Model | Recommended circuit* |
|
| |
1791257 (2HP 1PH 230V) | 30 Amp | |
|
|
|
1791258 | (3HP 3PH 230V) | 30 Amp |
|
|
|
1791258 | (3HP 3PH 460V) | 15 Amp |
|
| |
1791259 (3HP 1PH 230V) | 30 Amp | |
|
| |
1791260 (5HP 3PH 230V) | 40 Amp | |
|
| |
1791260 (5HP 3PH 460V) | 20 Amp |
*subject to local codes
Table 1
Recommended Gauges (AWG) of Extension Cords
|
|
| Extension Cord Length * |
| |||
|
|
|
|
|
|
|
|
Amps | 25 | 50 | 75 | 100 | 150 | 200 | |
feet | feet | feet | feet | feet | feet | ||
|
|
|
|
|
|
|
|
< 5 |
| 16 | 16 | 16 | 14 | 12 | 12 |
|
|
|
|
|
|
|
|
5 to | 8 | 16 | 16 | 14 | 12 | 10 | NR |
|
|
|
|
|
|
| |
8 to 12 | 14 | 14 | 12 | 10 | NR | NR | |
|
|
|
|
|
|
|
|
12 to | 15 | 12 | 12 | 10 | 10 | NR | NR |
|
|
|
|
|
|
|
|
15 to | 20 | 10 | 10 | 10 | NR | NR | NR |
|
|
|
|
|
|
|
|
21 to | 30 | 10 | NR | NR | NR | NR | NR |
|
|
|
|
|
|
|
|
*based on limiting the line voltage drop to 5V at 150% of the rated amperes.
NR: Not Recommended.
Figure 7
If you are connecting a plug, use a proper UL/CSA listed
If the Band Saw is to be
During
13