6.Riving knife must be parallel to saw blade. See section 9.6 for inspection and adjustments.

NOTE: A low-profile riving knife is also provided, for making non-through cuts on the table saw.

7.14Anti-kickback pawls

Refer to Figure 12.

1.Install insert plate into table.

2.Position anti-kickback pawl assembly (H) as shown in Figure 12; the angled side of pawl block faces toward front of saw.

3.Lower pawl assembly onto center notch of riving knife, with pawls straddling knife. Push and hold button on pawl block (on opposite side of that shown in Figure 12), and push pawl block down until it securely engages in notch.

4.Allow pawls to drop freely to the table.

7.15Blade guard

Refer to Figure 12.

1.Push and hold button (J1) at back end of guard.

2.Push guard (J) down at an angle, as shown, until pin engages rear slot in riving knife, then push down front of guard until it seats properly, and is parallel to table top.

3.Release button (J1). The transparent guard leaves (K) should drop freely to the table.

4.Lift up on guard assembly to verify proper seating.

NOTE: The transparent leaves can be kept in raised position by lifting them up and forward.

Guard and pawl assemblies must be securely installed, and leaves must be in contact with table, before beginning any through-cutting operation.

The bracket and clamp plate (E/F, Figure 12) are adjusted at the factory and no further adjustment of the blade guard and riving knife assembly should be necessary. However, proper alignment is very important. Before operating table saw, read section 9.6 ,Riving knife alignment, to verify and follow adjustment procedure if necessary.

7.16Dust chute

Use of a dust collection system (not provided) is strongly recommended during table saw operation. It will help keep the shop clean, as well as prevent potential health issues due to dust inhalation.

Attach dust collection hose to the 4-inch dust port at base of saw, and secure with a wire hose clamp (not provided).

8.0Electrical connections

The PM1000 table saw is rated at 115/230V power, and is pre-wired for 115 volt. The table saw comes with a plug designed for use on a circuit with a grounded outlet that looks like the one pictured in A, Figure 13.

Before connecting to power source, be sure switch is in off position.

It is recommended that the table saw be connected to a dedicated 20 amp circuit with breaker or time- delay fuse marked “D”. Local codes take precedence over recommendations.

8.1Grounding instructions

1. All Grounded, Cord-connected Tools:

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment- grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded. Failure to comply may cause serious or fatal injury.

Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool's plug.

Repair or replace damaged or worn cord immediately.

14

Page 14
Image 14
Powermatic pm1000 Electrical connections, Anti-kickback pawls, Blade guard, Dust chute, Grounding instructions