Setting Up the Console 25

Set Resistance Range (Bike only)

Value Range: High, Medium, or Low
(Default: High)
You can set a low, medium, or high base resistance on the
recumbent or upright bikes. There are 25 levels of resistance
within each base setting, but the base setting affects the
overall resistance range. The following ranges are available:
High: Provides full resistance range.
Medium: Provides approximately two thirds of the
resistance that is available within the high group setting.
Low: Provides approximately one third of the resistance
that is available within the high group setting.

Set Crossramp Auto Level (EFX Dual only)

Value Range: 0 to 20
(Default: 10)
Use this setting to choose a specific ramp incline so that the
EFX automatically returns to that incline at the end of a
workout session.

Viewing the Informational Displays

Information Display settings are values that provide you with
information about the equipment. Types of information
contained in this setting group include, an event log, software
and equipment serial numbers, and usage information.
To view the System settings:
1. At the Welcome banner, press Pause.
2. Press the following number keys in sequence to enter the
password:
6 5
3. Press Enter.
Use the following table to set up customized Informational
Display values.