4 - Use in Standard Mode

Starting operation

Press the power button4 - Use in Standard Mode when the unit has received the signal it gives out two 'beep' tones. The operation light switches on and the heat pump water heater starts operation. The compressor will restart after 3 minutes to protect the system if the interval is shorter than 3 minutes from the last shut down to the present switch on.

Mode Selection

Press the 'M' button to chose the mode of heating and cooling (this key is invalid for the single water chiller or single water heater)

Temperature Setting Selection

1)Press "Temperature Adjustment Button Starting operation to set the temperature 1 degree higher

2)Press "Temperature Adjustment Button Mode Selection to set the temperature 1 degree higher

3)Temperature range is set in heating mode: 45°C to + 55°C (Single water chiller is without this function)

4)Temperature range is set in cooling mode: 10°C to + 35°C (Single water heater is without this function)

Timer Switch On

1)When the heater is off press the Temperature Setting Selectiontimer-on button to set time for the timer-on switch. Press the button once to change the time interval of 1 hour in a cyclic manner of 1,2,...24,1,2 (The display shows the previous time as the starting time of the present setting)

2)When it reaches the switch-on time, the heat pump water heater will operate in the preset time mode.

3)Press the timer-on Timer Switch On button again, and the set up is cancelled.

4)If the on/off Timer-Off Switch button is pressed while the unit is under the timer on setting, the unit will start immediately. The timer setting is at that point cancelled.

Timer-Off Switch

1)When the heater is on, press theManual backgroundtimer-on button to set time for the timer-on switch. Press the button once to change the time interval of 1 hour in a cyclic manner of 1,2,...24,1,2 (The display shows the previous time as the starting time of the present setting)