Pride Mobility INFMANU3210 manual Troubleshooting, Lift will not Operate, Lift Stops Operating

Models: INFMANU3210

1 24
Download 24 pages 35.62 Kb
Page 19
Image 19

V . T R O U B L E S H O O T I N G

LIFT WILL NOT OPERATE

Check the circuit breaker reset button. Reset if nec- essary. See figures 21 and 22.

Ensure all harness connections are secure.

Ensure the power wire leading to the positive battery terminal is tight and not corroded.

Check the fuse located on the red power wire near the battery. If blown, replace with a new 25-amp fuse. See figure 23.

WARNING! Do not use a higher rated fuse than 25-amp. Doing so may damage the lift’s electrical system.

WARNING! The replacement fuse must exactly match the rating of the old fuse. Failure to use properly rated fuses may cause damage to the electrical system.

LIFT STOPS OPERATING

If your SilverBoom is heavily strained because of ex- cessive loads, the main circuit breaker (see figures 21 and 22) may trip to protect the motor and electron- ics from damage. When the breaker trips, the entire electrical system shuts down.

WARNING! Never attempt to lift more than 300 lbs. (136 kg) with the SilverBoom 300.

To reset the main circuit breaker:

1.Allow a minute or so for the electronics to “cool.”

2.Push in the reset button to reset the breaker.

If the breaker trips frequently, contact your authorized Pride Provider.

CIRCUIT BREAKER RESET BUTTON

Figure 21. Circuit Breaker Reset Button SilverBoom 300

CIRCUIT BREAKER RESET BUTTON

Figure 22. Circuit Breaker Reset Button Power Rotating Base Models

WORKING FUSE

BLOWN FUSE

Figure 23. Fuse Replacement

 

SilverBoom 300

www.silverstarlifts.com

19

Page 19
Image 19
Pride Mobility INFMANU3210 Troubleshooting, Lift will not Operate, Lift Stops Operating, To reset the main circuit breaker