X . C A R E A N D M A I N T E N A N C E

CORRECTIVE MAINTENANCE

If the battery indicator gauge does not light up when you turn on the power:

νCheck the harness connections. Make sure they are tight.

νCheck the circuit breaker. Reset it if necessary.

νCheck the battery connections.

If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are available at automotive parts stores. Disconnect both batteries before load testing and follow the direc- tions that come with the load tester. If either one of the batteries fails the load test, replace both of them. If your Jazzy 1105 still does not power up, contact your authorized Pride provider.

NEW

MOTOR

WORNBRUSHES

MOTOR

BRUSH

MOTOR

BRUSH

CAP

 

 

MOTOR

 

 

BRUSH CAP

 

 

(OPPOSITE

Figure 34. Motor

 

SIDE)

 

Figure 35. Motor Brushes

Jazzy 1105/RevH/Feb03

www.pridemobility.com

41

Page 41
Image 41
Pride Mobility Jazzy 1105 owner manual Corrective Maintenance, Motor