V . Y O U R V I C T O R Y X L - 4

Main Circuit Breaker (Reset Button)

When the voltage in the batteries becomes low or your scooter is heavily strained because of excessive loads, the main circuit breaker may trip to protect the motor and electronics from damage. When the breaker trips, the entire electrical system shuts down.

νThe main circuit breaker reset button is located next to the ammeter. See figure 9.

νThe reset button pops out when the breaker trips.

νAllow a minute or so for the electronics to “rest.”

νPush in the reset button to reset the breaker.

νIf the breaker trips frequently, you may need to charge the batteries more often or have your authorized Pride Provider perform a load test on the batteries.

Fuses (Not Shown)

There is a fuse located on each side of the rear section, to protect the controller if any of the lights short out. The fuses are part of the rear light assembly located on the underside of the shroud. To replace a fuse, first remove the rear shroud. Lift the rubber cap that opens the fuse box and replace the old fuse with a 2-amp fuse.

NOTE: Fuses used in the scooter are the same type that are used in automobiles.

24

www.pridemobility.com

Victory XL-4/RevC/June03

Page 24
Image 24
Pride Mobility SC2700 owner manual Main Circuit Breaker Reset Button, Fuses Not Shown